  1. E

    Hughes Auto former Indicated Amp on line one was Overloaded (Front AC ISSUE)

    Pole one on the Hughes Protector is tripping. I've narrowed it down to the front AC. I've pulled the cover and the compressor capacitor looks fine. However, the fan capacitor has one burnt wire. I don't have a meter to check each one. I'm hoping the compressor itself isn't fried. 1- Could it be...
  2. E

    2018 Bighorn FB3780 electric schematics

    Does anyone have any suggestions to get the electric schematics for my 2028 Bighorn 3870. I need a full diagram, and also assume the charger is located in the rear underbelly. As it’s not in the garage. My mechanic came down and test all electronics, and I’d requesting the schematics. Thanks David
  3. E

    Leak Between Dump Valve and Tank

    This is the leak between the valve and the tank. I’m not certain how their connected. The hose strap is tight. Sooo, what and/or how is it connected that could cause this leak? Thanks so much: David
  4. E

    Leak under front underbelly.

    Hi, I have an intermittent leak under the front underbelly, indicated by an occasional drip coming from the front underbelly. I had to make a small cut in the underbelly in order to let the water drain out. (Not a lot, enough!!) I let the black tank get full ( pressure??) and did laundry today...
  5. E

    Standard Electric Fireplace Problem

    My electric fireplace will only blow heat for a few minutes the the heat shuts off. This is regardless of the settings. Any input would be helpful!! Regards, David
  6. E

    Black Tank Won’t Drain

    It’s gotten cold here in St Louis, however, the temperature has warmed up enough to thaw the drain pipes. Originally, the black tank valve was frozen, and would not budge. Since it’s warmed up constantly for a few day’s, the valve opens freely. However, it’s not draining. I have tank heaters...
  7. E

    Adjusting the Sundance Slide Out Awning

    How do I adjust my Sundance awning so water doesn’t pool up? Thanks for your input. David
  8. E

    Furrion Oven Won’t Stay Lit

    My Furrion oven won’t stay lit after multiple attempts. Seems every time I light it and close the oven door the flame goes out. Thanks, David
  9. E

    Max Lift of all Stabilizers

    I recently was in a flash flood. Water entered in the lower front of my rig, dropped the under belly, fortunately no damage. So to my point: If I wanted to override the leveling stabilizer, and lift the rig front and back to their highest point. (I.e) lifting the rig off the ground; how do I...
  10. E

    SOLVED: Froze up: Where are the low point drains on a 3870

    It’s 0° outside and I’m froze up. My Spicket and water hose supply are both heated and functioning. I am heating the water control compartment, as well as running the furnace. I’ve read that the low point drains can also be the culprit. However, embarrassing to say, after owning many rigs, I...
  11. E

    Black Tanks Won’t Flush

    I have two black tanks that drain out of a single discharge. In the water control cabinet there are two unmarked flush connections. When I connect to one there is no flow. When connected to the other it shoots the water out of the other flush connection. I tried a Y connection, still nothing...
  12. E

    Two black tank flush connections.

    Good morning, this rig has two black tanks. In addition, inside the compartment there are two black tank flush connections. When I hook the hose up to one connection it appears to be flowing appropriately. However, when I connect to the other water shoots out of the unconnected inlet. I’ve...
  13. E

    PEX Line connection replacement. Suggestiosn?

    This connection is in need of replacement: what diameter water supply line is it, and what size parts and procedure is required to do so? I realize it has the crimping connection and was going to replace with a hose clamp. Is there a way to remove the crimp with out the correct removal tool...
  14. E

    Heartland Refuses To Authorize Warranty Work

    There were several warranty issues submitted to Heartland for blatant constructional issues. They refuse to authorize reimbursement for repairs done by a Certified Master Technician. We all spent a substantial amount of money for these rigs, only to find out there is no support from the...
  15. E

    Alternative to lethal weapon.

    I was a street medic/Eng for 30 plus years, retired and now work in a Super Max Prison as an RN. Now, I definately carry a fire arm, as I've had many valid threats from offenders. Not so much anymore as we've earned mutual respect for one another. However, the custody officer's exposed one on...
  16. E

    Slide out leaking,. Lots of rain coming.

    I have two hydraulic slides in the kitchen and living area. Woke up this morning to h2o everywhere. The slide out leaking has a bow in the center and the water is dripping directly in the center. Slide out awning is not helping. I work night's and thank God I was off, as to wake up early on and...