  1. AnthonyA

    All electric slides are dead

    Yep! I relabled it and checked the rest. All good now. I appreciate everyone's help!
  2. AnthonyA

    All electric slides are dead

    Me too. I figured it was something simple. At least I know all the components of the slide system are good
  3. AnthonyA

    All electric slides are dead

    Yep. That is for the actual Bed lifting mechanism.
  4. AnthonyA

    All electric slides are dead

    Ok, we have victory! So it turns out that a 15 amp fuse named (Ceiling Lights) was burnt and was directly tied to the Rocker Panel switches for the Electric slides only...my hydraulic slides worked fine. Had to use a 20 amp until I can get some more 15 amp fuses. Funny thing is, this fuse has...
  5. AnthonyA

    All electric slides are dead

    Ok, I have an update. I was able to run a isolated (direct) 12v source to one of the motors and still no response. (Testing done with and without shore power) I am showing 14.75/12.8 volts at the controller J7/J8 power input side. I am also showing the same voltage on the switch side (J8 +...
  6. AnthonyA

    All electric slides are dead

    It looks like this may be what I have to do since I am getting power at all 3 controllers. Haven't tested power out to motors yet. Will have to check that tomorrow. It's just so odd that all 3 controllers are having the same issue.
  7. AnthonyA

    All electric slides are dead

    I am getting power at all 3 controllers, not sure if this is possible or not with a short. As soon as I plug power back in, it goes back to the 9 blinks. I find it extremely odd that all 3 would be experiencing the same issue. I may have to chase the brown wires down 1 by one.
  8. AnthonyA

    All electric slides are dead

    Yep, sure do. 13.4 to 13.8 on both ends.
  9. AnthonyA

    All electric slides are dead

    Yes, just checked the 80 amp buss, 13.8 in and out. Same for the one up top.
  10. AnthonyA

    All electric slides are dead

    Yes, definitely odd. This leads me to believe that there is a some component that has the ability to shut down all 3 slides. I replaced the batteries because they didn't hold a load, but that still didn't do a thing.
  11. AnthonyA

    All electric slides are dead

    The Batteries were definitely weak as they did not hold a load. I bought some new ones and still nothing. Manual bypass does nothing either. What could cause all 3 slides to be dead? There has to be some kind of master control or fuse that operates all 3. The only thing I did recently was...
  12. AnthonyA

    All electric slides are dead

    I am preparing for a move and noticed that all 3 Schwintek Slides are giving a Error Code #9 for a "Hall pwr short to GND". I hear zero activity when I press the switches to pull the slides in. I tried the manual override, lights started flashing, but no action. I have checked the 2 breakers...
  13. AnthonyA

    RESOLVED - No power to Control panel

    Re: No power to Control panel Got it! Turned out it was a fuse on the Relay Board. Thanks again for all the help! Sent from my SM-G965U using Tapatalk
  14. AnthonyA

    RESOLVED - No power to Control panel

    Re: No power to Control panel I do not. I opened the KIB panel looking for something with fuses and saw nothing. Also, I am not a 100% sure what I am looking for. Do you have a picture? Sent from my SM-G965U using Tapatalk
  15. AnthonyA

    RESOLVED - No power to Control panel

    Re: No power to Control panel Yes, all those are working which is why I am stumped. I read 14.8V to 14.9V coming in to LCI panel. I have power coming into to the light switch panel (KIB) Awhich is why I suspected some kind of relay/remote connected to the blue wire? Sent from my SM-G965U using...